This drawing presents RCC column footing detail with a 4ft by 4ft footing base and reinforced column section used in structural construction planning. The column details drawing illustrates the structural arrangement from the foundation footing up to the plinth level, including reinforcement and beam connection. The footing plan clearly shows a 4ft by 4ft square footing with reinforcement bars of 12mm diameter placed on both sides at 5-inch spacing forming the base structural grid. The column size is shown as 10 inches by 10 inches with vertical reinforcement using 16mm diameter bars, with four bars provided in the column core. The structural layout also includes 6mm diameter stirrups placed at 15cm spacing to hold the reinforcement cage and maintain structural stability.