Trimix Road Construction Detail Drawing With Reinforcement Layers
<p><span style="background-color: transparent; color: rgb(0, 0, 0);">This AutoCAD DWG Trimix road </span><a href="https://cadbull.com/Construction-Cad-Drawing" rel="noopener noreferrer" target="_blank" style="background-color: transparent; color: rgb(17, 85, 204);"><strong>construction</strong> </a><span style="background-color: transparent; color: rgb(0, 0, 0);">detail drawing illustrates a typical section with clearly defined structural layers and measurements. The drawing shows a 200 mm thick Trimix concrete layer </span><a href="https://cadbull.com/Rcc-detail-cad-drawing" rel="noopener noreferrer" target="_blank" style="background-color: transparent; color: rgb(17, 85, 204);"><strong>reinforced</strong></a><span style="background-color: transparent; color: rgb(0, 0, 0);"> with 8 mm diameter bars placed at 200 mm center to center in both directions, finished with a 50 mm floor hardener as approved by the vendor. </span></p><p><span style="background-color: transparent; color: rgb(0, 0, 0);">Below the Trimix layer, a 125 micron PVC sheet is provided as a separation layer over a 150 mm thick PCC base. The foundation includes a 230 mm thick granular sub-base laid over compacted earth compacted to 95 percent of MDD layer-wise. All dimensions are indicated in millimeters, and the drawing is suitable for execution reference, quality checks, and construction coordination for rigid pavement works.</span></p>