Column Footing Detail Interior 0.80 x 0.80 Exterior 0.60 x 0.80

Ratings & Reviews
Be the first to share your experience with this product. Your review helps others make better decisions!
Description
Column footing reinforcement detail drawing showing interior and exterior footing construction used in structural foundation design. The drawing illustrates two footing types, including an interior footing sized 0.80 x 0.80 and an exterior footing sized 0.60 x 0.80, designed to support reinforced concrete columns. Reinforcement arrangement is clearly indicated with 5 N3 bars spaced at 0.16 in both directions for the interior footing with a footing length of 1.10. Additional reinforcement includes 4 N3 bars spaced at 0.15 with column anchorage length of 1.10, providing structural stability between the column and footing base.